Citation: | ZHAO Li, YAN Bo, CAI Meng-qi, WU Chuan. Numerical Investigation on Galloping Characteristics of Continuous Multi-Span Iced Quad Bundle Conductor Lines[J]. Applied Mathematics and Mechanics, 2014, 35(5): 487-497. doi: 10.3879/j.issn.1000-0887.2014.05.003 |
[1] |
Chan J, Havard D, Rawlins C, Diana G, Cloutier L, Lilien J-L, Hardy C, Wang J, Goel A.Wind-Induced Conductor Motion [M]. 2nd ed. EPRI transmission line reference book. Electric Power Research Institute. Palo Alto, USA: EPRI, 2009.
|
[2] |
Hartog J P Den. Transmission line vibration due to sleet[J].Transactions of the American Institute of Electrical Engineers,1932,51(4): 1074-1086.
|
[3] |
Nigol O, Clarke G J. Conductor galloping and control based on torsional mechanism[C]//IEEE Power Engng Soc Meeting.paper no C74016-2. New York, 1974.
|
[4] |
Yu P, Desai Y M, Popplewell N, Shah A H. 3-degree-of-freedom model for galloping-2[J].Journal of Engineering Mechanics,1993,119(12): 2426-2428.
|
[5] |
Jones K F. Coupled vertical and horizontal galloping[J]. Journal of Engineering Mechanics,1992,118(1): 92-107.
|
[6] |
Desal Y M, Yu P, Popplewell N, Shah A H. Finite element modeling of transmission line galloping[J].Computers & Structures,1995,57(3): 407-420.
|
[7] |
Luongo A, Zulli D, Piccardo G. Analytical and numerical approaches to nonlinear galloping of internally resonant suspended cables[J].Journal of Sound and Vibration,2008,315(3): 375-393.
|
[8] |
王丽新, 杨文兵, 杨新华, 袁俊杰. 输电线路舞动的有限元分析[J]. 华中科技大学学报(城市科学版), 2004,21(1): 76-80.(WANG Li-xin, YANG Wen-bing, YANG Xin-hua, YUAN Jun-jie. Finite element analysis for galloping process of transmission lines[J].Journal of Huazhong University of Science and Technology(Urban Science Edition),2004,21(1): 76-80.(in Chinese))
|
[9] |
刘小会, 严波, 张宏雁, 周松. 覆冰导线舞动非线性数值模拟方法[J]. 应用数学和力学, 2009,30(4): 457-468.(LIU Xiao-hui, YAN Bo, ZHANG Hong-yan, ZHOU Song. Nonlinear numerical simulation method for galloping of iced conductor[J].Applied Mathematics and Mechanics,2009,30(4): 457-468.(in Chinese))
|
[10] |
HU Jing, YAN Bo, ZHOU Song, ZHANG Hong-yan. Numerical investigation on galloping of iced quad bundle conductors [J].IEEE Transactions on Power Delivery,2012,27(2): 784-792.
|
[11] |
严波, 李文蕴, 周松, 张宏雁. 覆冰四分裂导线舞动数值模拟研究[J]. 振动与冲击, 2010,29(9): 102-107.(YAN Bo, LI Wen-yun, ZHOU Song, ZHANG Hong-yan. Numerical simulation on galloping of iced quad-bundled conductor[J].Journal of Vibration and Shock,2010,29(9):102-107.(in Chinese))
|
[12] |
李黎, 陈元坤, 夏正春, 曹化锦. 覆冰导线舞动的非线性数值仿真研究[J]. 振动与冲击, 2011,30(8): 107-111.(LI Li, CHEN Yuan-kun, XIA Zheng-chun, CAO Hua-jin. Nonlinear numerical simulation study of iced conductor galloping [J].Journal of Vibration and Shock,2011,30(8): 107-111.(in Chinese))
|
[13] |
严波, 刘小会, 赵莉, 周林抒. 存在内共振的覆冰四分裂导线的非线性舞动[J]. 应用数学和力学, 2014,35(1): 39-49.(YAN Bo, LIU Xiao-hui, ZHAO Li, ZHOU Lin-shu. Nonlinear galloping of iced quad-bundle conductors with internal resonances[J].Applied Mathematics and Mechanics, 2014,35(1): 39-49.(in Chinese))
|
[14] |
Chabart O, Lilien J L. Galloping of electrical lines in wind tunnel facilities[J].Journal of Wind Engineering and Industrial Aerodynamics,1998,74/76: 967-976.
|
[15] |
李万平, 杨新祥, 张立志. 覆冰导线群的静气动力特性[J]. 空气动力学学报, 1995,13(4): 427-433.(LI Wan-ping, YANG Xing-xiang, ZHANG Li-zhi. Static aerodynamic characteristics of the galloping of bundled iced power transmission lines[J].Acta Aerodynamica Sinica,1995,13(4): 427-433.(in Chinese))
|
[16] |
张宏雁, 严波, 周松, 胡景, 刘小会. 覆冰四分裂导线静态气动力特性试验研究[J]. 空气动力学报[J]. 2011,29(2): 23-27.(ZHANG Hong-yan, YAN Bo, ZHOU Song, HU Jing, LIU Xiao-hui. Static test on aerodynamic characteristics of iced quad bundled conductors [J].Acta Aerodynamica Sinica,2011,29(2): 23-27.(in Chinese))
|
[17] |
Guring C B, Yamaguchu H, Yukino T. Identification of large amplitude wind-induced vibration of ice-accreted transmission lines based on field observed data[J].Engineering Structures,2002,24(2): 179-188.
|
[18] |
Dyke P V, Laneville A. Galloping of a single conductor covered with aD -section on a high-voltage overhead test lines[J].Journal of Wind Engineering and Industrial Aerodynamics,2008,96(6/7): 1141-1151.
|
[19] |
郭应龙, 李国兴, 尤传永. 输电线路舞动[M]. 北京: 中国电力出版社, 2002.(GUO Ying-long, LI Guo-xing, YOU Chuan-yong.Galloping of Transmission Lines [M]. Beijing: China Electric Power Press, 2002.(in Chinese))
|
[20] |
赵高煜, 何锃. 安装失谐摆的大跨越分裂导线自由振动计算[J].中国电机工程学报, 2003,23(2): 63-66.(ZHAO Gao-yu, HE Zeng. Free vibration analysis of long span bundled multi-conductor of the transmission line in detuning pendulums connected to spacers[J].Proceedings of the CSEE,2003,23(2): 63-66.(in Chinese))
|
[21] |
胡景, 严波, 祖正华, 周松, 张宏雁. 一种新型防舞器及其机理研究[J]. 工程力学, 2011,28(9): 200-206.(HU Jing, YAN Bo, ZU Zheng-hua, ZHOU Song, ZHANG Hong-yan. A new anti-galloping device and investigation on its mechanism[J].Engineering Mechanics,2011,28(9): 200-206.(in Chinese))
|